The heating-requirement calculator gives an estimate of how many watts you need to keep the living area warm when it is cold outside. The result is an order of magnitude, not an exact figure, and it is based on assumptions about insulation and ventilation.

An estimate. The result uses simplified physics and assumptions about insulation and ventilation. It gives an order of magnitude, not an exact value.

This calculator requires JavaScript. Turn on JavaScript in your browser to see the results.

Units:

1. The living area

2. Results

Heating output needed–

With a 30 % margin–

Energy per day–

Need at different outside temperatures (with a 30 % margin)
OutsideOutputWith margin

Read the guide: diesel heaters in a motorhome (in Swedish)

Good to know: The calculator is for guidance only. Values marked as assumptions are our estimates and can be changed to your own. Always follow the manufacturer’s instructions. See also the disclaimer.

Next steps: Diesel heater in a motorhome (in Swedish) · Insulating a campervan without condensation (in Swedish) · Campervan conversion: build order and checks

How the calculator works

Loss through the shell = U-value × area × temperature difference. The area is counted as a box: 2 × (length × width + length × height + width × height). The U-values for each insulation level are our assumptions.

Loss through ventilation = 0.34 × volume × air changes × temperature difference. 0.34 Wh per cubic metre per degree is roughly how much energy it takes to heat air.

Margin. The calculator adds 30 per cent for wind, windows and a door being opened, so that the recommendation is on the high side.

Ventilation must never be closed off. Install the heater according to the manufacturer’s instructions and have a carbon monoxide alarm.

Frequently asked questions about heating requirement

How large a diesel heater do I need?

For an insulated panel van a heater of about 2 kW is often enough, while larger vans and motorhomes in severe cold may need around 4 kW. The calculator gives an estimate based on size, insulation and outside temperature and adds a 30 per cent margin.

How accurate is the calculation?

It is an estimate. U-values and air changes are assumptions, and the real result is affected by windows, cold bridges, wind and how often the door is opened. Use the result as an order of magnitude.

Can I close the ventilation to save heat?

No. Ventilation is needed for oxygen and to carry moisture away. Heaters must be installed according to the manufacturer’s instructions, and a carbon monoxide alarm is recommended.

Read more

  • Diesel heaters in a motorhome
  • Insulate a campervan and avoid condensation
  • LPG calculator