Campervan cable size calculator (12V/24V)
The cable size calculator works out the conductor size a circuit in your campervan or motorhome needs. You enter current or power, cable length and the type of circuit. The calculator gives you the minimum cross-section for the voltage drop, a recommended standard size that also copes with the current and the fuse, and a fuse that protects the cable.
Choose the rule set
The English calculator is a separate copy of the Swedish tool. You choose which rule set to use. The calculation method and the figures below are unchanged from the Swedish tool.
- Swedish rules — voltage drop, standard sizes in mm², current-carrying capacity and fusing as described on this page (ISO 13297 and ISO 10133 as the current-capacity reference, together with the tool’s own voltage-drop and fuse assumptions).
- US rules (AWG). When this mode is selected, the calculator uses AWG wire sizes and the voltage-drop, ampacity and fuse figures from the US-mode underlay. The basis is US marine sources, not RVIA or NEC originals — see the notice below.
About the US rules option. When you choose US rules, the calculator uses AWG wire sizes and values from publicly available US marine sources: the allowable-amperage table in US Coast Guard regulation 33 CFR 183, which legally applies only to certain boats, and the voltage-drop limits (3 % and 10 %) and fuse-placement rules of the American Boat & Yacht Council’s standard ABYC E-11, as published in summaries by ABYC and equipment manufacturers. These are boat standards, not RV or vehicle standards, and they are not the RVIA or NEC originals. We use them because they are publicly documented, while the RV-specific standards are not freely available. New RVs built by RV Industry Association members follow NFPA 1192 and the ANSI/RVIA DC standard, and the 120 V side of an RV is covered by the National Electrical Code (NFPA 70, Article 551). There is no single federal rule for low-voltage wiring in campervans and RVs, and requirements can differ between states, between vehicle types (RV, campervan, boat, trailer), and between inspection bodies and insurers. The results are guidance only and do not replace any applicable law, code, regulation or standard, or the instructions from the manufacturer of your equipment. You are responsible for checking which rules apply to your vehicle and where you use it. Electrical faults can cause fire and serious injury: if you are in any doubt, ask someone qualified before you start.
1. The circuit
2. Results
Read the guide: cable size and fuses
3. Voltage drop in an existing cable
Already have a cable? Choose its size and the voltage drop is calculated with the same current, length and voltage as above.
4. Share the calculation
Safety: The calculator is a planning aid and applies to 12 V and 24 V direct current. Always follow the manufacturer’s instructions. In Sweden you do not need an electrician to wire 230 V in a motorhome or campervan; the requirement applies to buildings. Check the rules in your own country. Also read the disclaimer.
Next step: Campervan conversion: build order and checks
Swedish rules: how the cable calculator works
Current. If you enter power, it is divided by the system voltage: I = P / U. 300 W at 12 V is 25 A.
Minimum cross-section for the voltage drop. A = 2 × L × I × ρ / ΔU. L is the one-way cable length in metres, and the factor 2 includes the return cable. ρ is the resistivity of copper, 0.0175 Ω·mm²/m at room temperature. In a hot space or engine compartment the calculator uses 0.021, which corresponds to copper at about 70 °C.
Permitted voltage drop. Charging circuits (B2B chargers, solar controllers and battery chargers) may have at most 0.15 V at 12 V and 0.3 V at 24 V, because otherwise the charger measures the wrong voltage and charges less well. Sensitive equipment, inverters and diesel heaters may have at most 3%. Lighting and simpler loads may have up to 5%.
Standard size and current-carrying capacity. The result is rounded up to the next standard size: 0.75, 1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95 or 120 mm². A separately run conductor is at least 1.5 mm². The calculator also checks that the cable can carry the current and the fuse, using the table below, and steps up a size if needed.
Fuse. The fuse is the smallest standard size that is at least 1.25 times the current. It must not be larger than the cable can tolerate; if it would be, a heavier cable is chosen. The fuse should be placed as close as possible to the battery positive.
Swedish rules: example calculations
The examples are calculated with the same method as the calculator. Length is one way.
| Circuit | Type | System | Length | Current | Minimum area | Recommended cable | Voltage drop | Fuse |
|---|---|---|---|---|---|---|---|---|
| LED lighting 30 W | Lighting | 12 V | 4 m | 2.5 A | 0.58 mm² | 1.5 mm² | 0.23 V (1.9%) | 5 A |
| Compressor fridge 60 W | Sensitive | 12 V | 5 m | 5 A | 2.43 mm² | 2.5 mm² | 0.35 V (2.9%) | 7.5 A |
| Diesel heater 10 A | Sensitive | 12 V | 2 m | 10 A | 1.94 mm² | 2.5 mm² | 0.28 V (2.3%) | 15 A |
| Solar controller 20 A | Charging circuit | 12 V | 2 m | 20 A | 9.33 mm² | 10 mm² | 0.14 V (1.2%) | 25 A |
| B2B charger 30 A | Charging circuit | 12 V | 1.5 m | 30 A | 10.5 mm² | 16 mm² | 0.1 V (0.8%) | 40 A |
| B2B charger 30 A in engine compartment | Charging circuit, hot | 12 V | 4 m | 30 A | 33.6 mm² | 35 mm² | 0.14 V (1.2%) | 40 A |
| Inverter 2,000 W | Sensitive | 12 V | 1.5 m | 166.7 A | 24.31 mm² | 70 mm² | 0.12 V (1%) | 225 A |
| Inverter 2,000 W | Sensitive | 24 V | 1.5 m | 83.3 A | 6.08 mm² | 35 mm² | 0.12 V (0.5%) | 125 A |
The inverter example shows why current-carrying capacity governs at high currents. Voltage drop alone would be satisfied by 25 mm², but a 225 A fuse requires a cable that can carry at least 225 A.
Swedish rules: current-carrying capacity in the calculator
The calculator uses values for a single copper conductor with 70 °C insulation, with at most three conductors in a bunch, according to the table in ISO 13297 and ISO 10133 (standards for electrical systems in small craft, often used as a reference for 12 V and 24 V vehicles). In the engine compartment a factor of 0.75 applies for 70 °C insulation. Cable with insulation for a higher temperature can carry more, but the calculator uses 70 °C in order to stay on the safe side. If more conductors share the same bunch, current-carrying capacity falls further.
| Size | Current-carrying capacity | In engine compartment (× 0.75) |
|---|---|---|
| 0.75 mm² | 10 A | 7.5 A |
| 1.5 mm² | 18 A | 13.5 A |
| 2.5 mm² | 25 A | 18.8 A |
| 4 mm² | 35 A | 26.2 A |
| 6 mm² | 45 A | 33.8 A |
| 10 mm² | 65 A | 48.8 A |
| 16 mm² | 90 A | 67.5 A |
| 25 mm² | 120 A | 90 A |
| 35 mm² | 160 A | 120 A |
| 50 mm² | 210 A | 157.5 A |
| 70 mm² | 265 A | 198.8 A |
| 95 mm² | 310 A | 232.5 A |
| 120 mm² | 360 A | 270 A |
Sources: ISO 13297 and ISO 10133, Table A.1 (current-carrying capacity and correction factor for the engine compartment), (ISO 13297:2020). Insulation requirements in the engine compartment according to ISO 10133:2012, section 7.
The calculator is a planning aid and applies to 12 V and 24 V direct current. In Sweden you do not need an electrician to wire 230 V in a motorhome or campervan; the requirement applies to buildings. Check the rules in your own country. Read more in the disclaimer.
US rules (AWG): how the calculator works
In US mode the calculator works in AWG and feet. The voltage drop is calculated over the whole circuit, from the positive source to the load and back to the negative source, so the one-way length you enter is doubled.
Voltage drop. The required conductor area in circular mils is CM = 10.75 × I × L / E, where 10.75 is the resistance constant for copper, I is the current in amperes, L is the round-trip length in feet and E is the permitted voltage drop in volts. The calculator then picks the nearest AWG size that is at least that large. Critical circuits, such as the feed to a fuse panel, electronics and chargers, may have at most 3% (0.36 V at 12 V, 0.72 V at 24 V). Lighting and other non-critical loads may have up to 10% (1.2 V at 12 V, 2.4 V at 24 V). Which camper circuits count as critical is our own interpretation of the boat standard.
Ampacity. The wire must cope with both the voltage drop and the current. If the two give different sizes, the heavier wire applies. Ampacity comes from the allowable-amperage table for stranded copper in 33 CFR 183.425 (Table 5) and depends on the temperature rating of the insulation. Inside an engine compartment the calculator multiplies the table value by the correction factor in the table note and always rounds down. If you choose the conservative bundling option, it also multiplies by 0.70 (3 wires), 0.60 (4–6), 0.50 (7–24) or 0.40 (25 or more). The regulation only requires that derating for circuits of 50 V or more, so at 12 and 24 V it is an optional extra margin.
Smallest size. A separately run conductor must be at least 16 AWG. 18 AWG may only be used inside a sheathed multi-conductor cable and must not extend more than 30 inches outside the sheath (33 CFR 183.425(e)–(f)). The calculator warns you when the result is 18 AWG.
Fuse. The calculator suggests the nearest standard fuse at or above the load current and never above the wire’s ampacity, and steps up the wire if needed. For information it also shows the legal ceiling of 150% of the ampacity for circuits below 50 V (33 CFR 183.455(c)(1)). Always follow the fuse rating your equipment maker specifies.
Fuse placement. Fit the fuse or circuit breaker within 7 inches (175 mm) of the battery or other source, measured along the conductor. Up to 72 inches (1.83 m) is allowed only if the conductor is connected directly to the battery terminal and is in a sheath or enclosure its entire length. A conductor from another source, such as a bus bar or switch, may have up to 40 inches (1.02 m) if it is in a sheath or enclosure all the way. This follows the stricter ABYC E-11 rule; the federal boat rule allows 72 inches without the sheath requirement. Starter motor cables are exempt.
US rules: ampacity in the calculator
Values for a single stranded copper conductor, outside the engine compartment, by insulation temperature rating. mm² is calculated from the AWG definition.
| AWG | mm² | 60 °C | 75 °C | 90 °C | 105 °C | 125 °C |
|---|---|---|---|---|---|---|
| 18 | 0.82 | 10 A | 10 A | 20 A | 20 A | 25 A |
| 16 | 1.31 | 15 A | 15 A | 25 A | 25 A | 30 A |
| 14 | 2.08 | 20 A | 20 A | 30 A | 35 A | 40 A |
| 12 | 3.31 | 25 A | 25 A | 40 A | 45 A | 50 A |
| 10 | 5.26 | 40 A | 40 A | 55 A | 60 A | 70 A |
| 8 | 8.37 | 55 A | 65 A | 70 A | 80 A | 90 A |
| 6 | 13.30 | 80 A | 95 A | 100 A | 120 A | 125 A |
| 4 | 21.15 | 105 A | 125 A | 135 A | 160 A | 170 A |
| 3 | 26.67 | 120 A | 145 A | 155 A | 180 A | 195 A |
| 2 | 33.63 | 140 A | 170 A | 180 A | 210 A | 225 A |
| 1 | 42.41 | 165 A | 195 A | 210 A | 245 A | 265 A |
| 1/0 | 53.48 | 195 A | 230 A | 245 A | 285 A | 305 A |
| 2/0 | 67.43 | 225 A | 265 A | 285 A | 330 A | 355 A |
| 3/0 | 85.03 | 260 A | 310 A | 330 A | 385 A | 410 A |
| 4/0 | 107.22 | 300 A | 360 A | 385 A | 445 A | 475 A |
Engine compartment correction factors: 60 °C × 0.58, 75 °C × 0.75, 80 °C × 0.78, 90 °C × 0.82, 105 °C × 0.85, 125 °C × 0.89, 200 °C × 1.00. The calculator also offers 80 °C and 200 °C insulation.
Sources: 33 CFR 183.425, Table 5 and section 183.435(b) (bundling); 33 CFR 183.455 and 183.460 (fuses); ABYC, What Is Voltage Drop?; Ancor, Conductors Sized (AWG) for 3% Voltage Drop; Blue Sea Systems, DC Circuit Protection. All read on 13 November 2026.
Safety and the US rules option
About the US rules option. When you choose US rules, the calculator uses AWG wire sizes and values from publicly available US marine sources: the allowable-amperage table in US Coast Guard regulation 33 CFR 183, which legally applies only to certain boats, and the voltage-drop limits (3 % and 10 %) and fuse-placement rules of the American Boat & Yacht Council’s standard ABYC E-11, as published in summaries by ABYC and equipment manufacturers. These are boat standards, not RV or vehicle standards, and they are not the RVIA or NEC originals. We use them because they are publicly documented, while the RV-specific standards are not freely available. New RVs built by RV Industry Association members follow NFPA 1192 and the ANSI/RVIA DC standard, and the 120 V side of an RV is covered by the National Electrical Code (NFPA 70, Article 551). There is no single federal rule for low-voltage wiring in campervans and RVs, and requirements can differ between states, between vehicle types (RV, campervan, boat, trailer), and between inspection bodies and insurers. The results are guidance only and do not replace any applicable law, code, regulation or standard, or the instructions from the manufacturer of your equipment. You are responsible for checking which rules apply to your vehicle and where you use it. Electrical faults can cause fire and serious injury: if you are in any doubt, ask someone qualified before you start.
Read more about camper electrics
- Power calculator: battery, solar, B2B charger and inverter
- Cable size and fuses at 12 V
- Campervan electrical system: building 12 V
- B2B chargers and smart alternators
- All guides on electrics and off-grid
- All tools
Frequently asked questions about cable size and fuses
How is the cable size calculated? (Swedish rules)
The cross-section in mm² is 2 × the one-way cable length in metres × the current in amperes × 0.0175 (the resistivity of copper), divided by the permitted voltage drop in volts. The factor 2 is there because the current travels both out and back. Always round up to the next standard size and check that the cable can carry the current and the fuse.
How much voltage drop is acceptable? (Swedish rules)
For charging circuits such as B2B chargers and solar controllers, voltage drop should be kept around 0.1–0.15 V, because otherwise the charger will think the battery is fuller than it is. For inverters, diesel heaters and other sensitive equipment, 3% is a common limit. For lighting and simpler loads, up to about 5% will often work.
Do I measure the length one way or there and back? (Swedish rules)
The easiest approach is to measure the distance from the battery to the load. The calculator then uses twice that length, because the return cable matters just as much for voltage drop as the positive cable. If the return path is via the chassis instead, you should still use the full length, as a precaution.
How do I choose a fuse? (Swedish rules)
Choose a fuse that is at least about 1.25 times the current the load draws in normal use, but never larger than the cable can tolerate. The fuse protects the cable and should be placed as close as possible to the battery positive terminal. Also follow the manufacturer’s recommendation for, for example, inverters and B2B chargers.
What happens in a hot space or engine compartment? (Swedish rules)
Hot copper conducts less well, so resistance rises and voltage drop increases. The cable can also carry less current when the surroundings are hot. The calculator then uses a resistivity of 0.021 instead of 0.0175 and reduces current-carrying capacity to 75%. Cable in an engine compartment should have insulation for at least 70 °C and should tolerate oil and fuel.
Is 24 V better than 12 V?
At the same power, the current is halved at 24 V. That means slimmer cables, less heat and lower voltage drop, which is most noticeable with large inverters. The drawback is that many 12 V vehicle appliances then need a converter. For most campervans 12 V is enough, but from about 2,000 W of inverter capacity, 24 V is worth considering.