Campervan electrical calculator (12V)

Use this calculator to estimate daily energy use and to compare simplified energy and current scenarios, based on your own assumptions. The results do not choose products and do not verify an installation. Tick the appliances you use, adjust watts and hours, and the figures update at once.

Calculation could not be completed: the calculator requires JavaScript.

1. Choose appliances

Tick what you use. Enter operating power in watts (or current in amperes for DC) and hours per day. Fridge: compressor operating power × actual run time. 45 W × 8 h is an adjustable worked example (360 Wh, equivalent to a daily average of 15 W × 24 h). A daily average can be used with 24 hours for energy, but it is not a simultaneous operating power. If the row is included in the simultaneous-load or starting scenario, use operating power and actual run time instead. The tool does not itself distinguish a daily-average row from a running load. Do not reduce the run time a second time if the value is already an average.

For DC rows entered in A, daily energy is estimated as A × hours × a nominal 12.8 V (LiFePO4) or 12 V (AGM). This is a simplified energy model for 12 V battery systems, not a current-sizing calculation. Do not enter 24 V current directly here; use the equivalent power in W. The current must refer to the stated operating point.

ApplianceType and unitValueHours/daySimultaneous

2. Battery and conditions

3. Current in the simultaneous-load scenario

Tick “Simultaneous” on the loads that can run at the same time. The values below are product-dependent assumptions. Enter the manufacturer’s data or measured values; an empty field is reported as “not assessed”. Step 3 estimates current under load using your separate voltage assumptions. That voltage does not change the energy budget and must not be added as a further energy uplift. W divided by voltage is a constant-power model here, not a universal appliance curve.

4. Starting event (optional, one load at a time)

5. Results

Consumption–

Battery (energy)–

Solar panel – rough estimate–

Charging – simplified energy estimate–

Simultaneous 230 V power–

Inverter DC current–

Direct DC loads–

Battery current budget (steady)–

Starting scenario–

Planning arithmetic based on your assumptions, not an installation instruction. The current budget does not replace the manufacturer’s data for the battery, BMS, inverter, cable and fuse. Hours set to 0 produce no energy, but a load can still be included in the current scenario. Cable size and fusing are not assessed here.

Read the guide: planning a 12 V electrical system

Next steps: Campervan conversion: build order and checks · Planning a 12 V electrical system

You can also look at calculated DC voltage drop in the cable size calculator. That is not a validation of the cable’s current-carrying capacity, routing or fuse protection.

How the power calculator works

Daily consumption. For each appliance, power in watts is multiplied by the number of hours per day. Energy for appliances that run at 230 V through the inverter is divided by the chosen efficiency (default 90%); idle consumption outside load operation, and starting energy treated separately, are not included. For DC rows entered in A, daily energy is estimated as A × hours × a nominal 12.8 V (LiFePO4) or 12 V (AGM). That is a simplified energy model for 12 V battery systems, not a current-sizing calculation; do not enter 24 V current directly, use the equivalent power in W. The current must refer to the stated operating point. For a compressor fridge, enter the compressor’s operating power × actual run time: 45 W running for about one third of the day corresponds to 8 hours and 360 Wh, the same energy as a daily average of 15 W × 24 h. That is an adjustable worked example. A daily average can be used with 24 hours for energy, but it is not a simultaneous operating power. If the row is included in the simultaneous-load or starting scenario, use operating power and actual run time instead; the tool does not itself tell a daily-average row from a running load. Do not reduce the run time a second time if the value is already an average.

Battery (energy). Daily demand in watt-hours, multiplied by the number of full days without charging, divided by the nominal battery voltage (12.8 V for LiFePO4 and 12 V for AGM) and by the usable share. Energy planning assumes a usable share of 90% for LiFePO4 and 50% for AGM. Those are locked rules of thumb, not the battery’s permitted limits; check your own battery manual. The answer is rounded up to a worked example, not a recommended product size. Ah states capacity, not permitted current.

Solar panel – rough estimate. Demand is divided by the selected season’s sun hours per day and by a locked factor of 0.75. The rules of thumb are about 4.5 sun hours in summer (May–August), about 2 in spring and autumn, and about 0.5 in winter. This is not a site- or weather-specific forecast and not a guarantee of daily coverage. The winter result is uncertain and often small; plan another way to charge. The season changes the solar assumption, not the loads’ operating profile.

Charging – simplified energy estimate. Theoretical charge current and charge time according to the energy model, based on the driving time you enter. 20–60 A, and the AGM limit (about 0.2 × the rounded Ah display, which can be more than 0.2 × the calculated demand), are internal rule-of-thumb and display limits, not a product choice or a charge-current limit. Charge losses, absorption, simultaneous load, and limits in the vehicle or charger are not verified.

Simultaneous current. You mark which loads run at the same time. The calculator adds the 230 V loads’ active power and works out the inverter current on the DC side as that power divided by efficiency and by the lowest voltage at the inverter input. Direct DC loads are added separately (W loads as assumed constant power at your voltage, A loads as entered at the operating point you want to assess), and the sum is the battery’s steady current budget for that scenario only. Efficiency and voltages are product-dependent: enter the manufacturer’s values or measured values. The voltages in the current scenario do not change the energy budget. A starting event is calculated for one load at a time, using the starting value and duration you assume; it is not a validated inverter curve or a measured inrush current. No margin, purchase size, cable size or fuse is produced, and the result does not replace data sheets for the battery, BMS, inverter and cable.

Default values in the calculator

The table is a locked example with 90% efficiency and 12 V. It does not mirror the choices you make in the calculator. Wh/day is the appliance’s energy (watts × hours). The Ah at 12 V column is the energy drawn from the battery divided by 12 V and, for 230 V appliances, includes the conversion loss (÷ 0.9). The calculator uses a nominal 12.8 V for LiFePO4, so its Ah per day will be slightly lower than the table. Appliances marked * are pre-selected.

Appliance Watts Hours/day Wh/day Ah at 12 V
Compressor fridge: operating power × run time (worked example) * 45 8 360 30
LED lighting * 10 4 40 3.3
Phone charging (USB) * 10 3 30 2.5
Water pump * 50 0.3 15 1.2
Diesel heater (fan and pump) 15 8 120 10
Roof fan 20 4 80 6.7
Laptop (230 V) 60 3 180 16.7
12 V TV (24 inch) 30 2 60 5
Kettle via inverter (230 V) 2000 0.1 200 18.5
Induction hob via inverter (230 V) 1800 0.3 540 50
Coffee maker via inverter (230 V) 900 0.2 180 16.7
Total of pre-selected items (*) – – 445 37.1

Simplified energy flow – not a wiring diagram

The figure shows energy flows in a simplified 12 V example: the vehicle’s alternator via the B2B charger, the solar panel via an MPPT controller, and 230 V appliances via the inverter. It shows energy flows, not how components should be connected or protected.

Simplified energy flow – not a wiring diagramSimplified energy flow for a 12 V example: starter battery and alternator via a B2B charger, solar panel via an MPPT controller, leisure battery to a 12 V fuse box and an inverter for 230 V. Not a wiring diagram or a complete protection scheme: return conductors, all protection, earthing and 230 V protection are not shown. Starter batteryand alternatorSolar panelon the roofB2B charger(DC-DC)MPPTcontroller12 V fuseboxInverter230 V Leisurebattery FuseFuseEnergy flow, not a wiring diagram
Simplified energy flow for a 12 V example. This is not a wiring diagram or a complete protection scheme: return conductors, all protective devices, earthing and 230 V protection are not shown. Cable, fuse, BMS and connections must be designed separately by someone with the relevant vehicle-electrical competence.

Read more about camper electrics

Frequently asked questions about batteries and solar

How large a battery do I need in my campervan?

Start from Wh/day and the number of days without charging. The tool’s 90/50% figures are rules of thumb; permitted usable capacity and permitted current come from your own battery manual. No product size is recommended.

Will solar panels cover the camper’s power needs?

The result depends on location, weather, shading and your load profile. The season factors in this tool are simplified assumptions, not a guarantee of charge balance.

What is a B2B charger, and do I need one?

A DC-DC charger can control charge current and charge profile between the vehicle and the living-area battery. Whether you need one, and whether it is compatible, must be judged against the documentation for the vehicle, the battery and the charger.

How large an inverter do I need?

Add up the 230 V appliances that can be on at the same time. Use the sum of their active power, not only the largest appliance. Then compare that with the inverter’s continuous power at the relevant temperature, and separately check the appliances’ starting events against the inverter’s peak power and how long it can sustain that peak, according to the data sheet. The calculator shows no margin and no purchase size. On the 12 V side, current is roughly the power divided by efficiency and by the lowest voltage at the inverter. The battery’s current budget also includes simultaneous 12 V loads.

Can I boil water or cook on induction through the inverter?

Yes, but the current is high. A kettle or induction hob may, for example, be around 1,500–2,200 W (an illustrative rule of thumb, not a verified product range). Energy per day is often modest because the appliances run for a short time, but the current while they run is what sets the demand. Worked example, not a setting recommendation: at 2,000 W, 90% efficiency and 11.5 V at the inverter, that is about 193 A on the 12 V side, plus any simultaneous 12 V loads. Ah states capacity, not permitted current: check the permitted current and duration for the battery, the BMS and the inverter in each data sheet.

How accurate is the power calculator?

It is a simplified planning estimate, not an electrical design or an installation instruction. Verify consumption by measurement and check product limits separately.